Mechanical Design, Manufacturing and Engineering Forum
DFM DFA Training and Trainers | Engineering and Design Data | Product Services Directory | Advertise
Engineering Forum | Engineering Specifications Forum |
Engineering and Drafting Store | ASME Y14.5M - 1994 GD&T Training
POSTING POLICY / RULES | Archive#1 | Archive #2 | Archive #3 | Calculators

Forum Moderators: Administrator

Beam design
Post Reply   Forum
Posted by: Chad Franke

04/03/2003, 14:15:07

Edit
Hello all. I am looking for some reassurance on a beam design. I am a mechanical engineer, but this isn't my specialty so I am looking for some reinforcement on my calculations. Here is the problem:

I need a beam (steel I Beam preferred) to span 45 feet. It will be simply supported, figure 44 feet between supports. There will be 2 point loads, actual estimated load of 6 kip. Spacing will be 17 feet from centerline. I am going for a factor of safety of 2-2.5. What size I beam would everyone recommend I use? Thanks for the help, this is a great resource site.











Post Reply | Recommend | Alert View All   | Next |

Replies to this message


Re: Beam design
Re: Beam design -- Chad Franke Post Reply Top of thread Forum
Posted by: wtool ?

09/01/2005, 10:32:43

Author Profile Mail author Edit
24" WF @ 68#/ft will deflect about 3/4" under the load

hope it is braced laterally

if truss depth is not a restricted, a truss could be less costly and more stable.







Post Reply | Recommend | Alert Where am I? Original Top of thread