Posted by: desmarkus ® 09/29/2004, 11:48:16 Author Profile Mail author Edit |
I'm desiging a hot water regulator. I'm pushing hot water through 4 loops which are around 150 feet long. The tubing I was going to use has a 3/8" I.D. with about 2.5 gpm flow... the pressure drops are huge. I used the pressure drop calc. found at the link below to calculate the pressure drop just through the pipe (no minor head loss) and got 160 psi! Does this sound right? this is 370 ft of head, I'd need a huge pump for that. carf-engineering.com Do I have my wires crossed? Is this pressure drop not related to Head? Or is my pipe just two small, 2.5 gpm isn't alot of water? Darryl; B.Sc.M.E. (E.I.T.); Gimli, Mb., Canada Modified by Administrator at Wed, Sep 29, 2004, 13:10:46 |
Post Reply | Recommend | Alert | Rate | View All | | | |
Replies to this message |
Re: Pump Sizing | |||
Re: Pump Sizing -- desmarkus | Post Reply | Top of thread | Forum |
Posted by: zekeman ® 10/01/2004, 22:21:28 Author Profile Mail author Edit |
I got f=.03 from charts based on a Reynolds number of 2000; the drop is .03*150/D*V^2/2g or about 150 feet of head loss for staight pipe. It will be higher considering the bends and loops. |