pipe stress
Post Reply   Forum
Posted by: jnb ®

08/17/2006, 14:27:36

Author Profile eMail author Edit

can someone direct me to some good information on how to solve bfp pipe stress issues







Post Reply | Tell a Friend (must be logged in) | Alert Admin About Post View All   | Next |

Replies to this message


Re: pipe stress
Re: pipe stress -- jnb Post Reply Top of thread Forum
Posted by: Kelly Bramble ®

08/17/2006, 14:46:15

Author Profile eMail author Edit

What are you trying to solve?







Post Reply | Tell a Friend (must be logged in) | Alert Admin About Post Where am I? Original Top of thread | |
Re: Re: pipe stress
Re: Re: pipe stress -- Kelly Bramble Post Reply Top of thread Forum
Posted by: jnb ®

08/17/2006, 15:01:18

Author Profile eMail author Edit

we have a flowserve 4x12 wxh-10 bfp that is going thru bearing at an alarming rate. alignment is good hot/cold, we have narrowed it down to pipe stress, which is a known fact. what i'm tasked to do is solve the piping problem. for a temp fix i intend to modify the spool pieces to fit the stress until we can come down for an extended period of time and redo the whole piping system. i was looking for some info on battering pipe, or diamond heating the pipe, to move it to where it will take the stress off the pump
any ideas







Post Reply | Tell a Friend (must be logged in) | Alert Admin About Post Where am I? Original Top of thread | |
Re: Re: Re: pipe stress
Re: Re: Re: pipe stress -- jnb Post Reply Top of thread Forum
Posted by: Kelly Bramble ®

08/17/2006, 15:51:42

Author Profile eMail author Edit

Just for clarity BFP stands for "Backflow Prevention"?

1. Can you attached a general configuration drawing to this forum thread for everybody to see?
2. You said the alignment was good hot/cold, how good (nothing is perfect)? What is the runout(s)?
3. How hot and cold is the bearings getting?
4. What kind of bearings? How are they lubricated? How are they cooled? What ar the operating conditions? What are the bearings rated at?
5. Where is the pipe stress coming from? Pressure?







Post Reply | Tell a Friend (must be logged in) | Alert Admin About Post Where am I? Original Top of thread | |
Re: Re: Re: Re: pipe stress
Re: Re: Re: Re: pipe stress -- Kelly Bramble Post Reply Top of thread Forum
Posted by: jnb ®

08/18/2006, 10:40:54

Author Profile eMail author Edit

thanks for the reply, but bfp stands for boiler feed pump. the alignment is within .002 with thermal growth added as per factory specs. the pressure is too high for bellows, i was just trying to get some tips about moving piping and the assocated hangers
thanks







Post Reply | Tell a Friend (must be logged in) | Alert Admin About Post Where am I? Original Top of thread