Posted by: jswiontek ®

06/29/2009, 14:32:11

Author Profile
eMail author
Edit

I am looking for some information regarding a class 5 interference thread fit (NC5-CSF). I recently inherited some products which use a Dorman double ended stud in which the base plate calls out for 9/16-12 NC5-CSF internal thread. I haven't been able to find much info on this thread class other than what it's application is. Can anyone point me to where I could find additional information?







Post Reply
Tell a Friend (must be logged in)
Alert Admin About Post
View All   | Next |

Replies to this message

: class 5 interference thread
: class 5 interference thread -- jswiontek Post Reply Top of thread Engineering Forum
Posted by: Kelly Bramble ®

07/07/2009, 09:08:58

Author Profile
eMail author
Edit

Welcome to the Engineers Edge!

The NC5-CSF designation is referenced in ANSIB1.21M and is generally used for copper and other soft alloy ( ferrous and non-ferrous) materials. In genenral this thread specification is for materials with interferance requiremnts and having a 160BB or less.

Also see DLA FED-STD-H28/23 specification.








Post Reply
Tell a Friend (must be logged in)
Alert Admin About Post
Where am I? Original Top of thread | |
: : class 5 interference thread
: : class 5 interference thread -- Kelly Bramble Post Reply Top of thread Engineering Forum
Posted by: Kelly Bramble ®

07/07/2009, 10:04:30

Author Profile
eMail author
Edit








Post Reply