Mechanical Design, Manufacturing and Engineering Forum
[ Home ] [ Search ] [ Engineering and Design Database ] [ Product and Services Directory ]
[ Engineering Forum ] [ DFM DFA Training and Trainers ] [ GD&T Training GD&T Trainers ] [ Advertise ]
[ Archive#1 ] [ Archive #2 ] [ Archive #3] [ Calculators ]
Forum Moderators: randykimball, Administrator

Determine thread length by pressure requirements.
Post Reply   Forum
Posted by: lancealot72 ®

05/24/2005, 13:36:37

Author Profile Mail author Edit
How would you go about calculating thread length based on an internal pressure of 100psi. i want to use a safety factor of about 4 so I need to design a thread length that will withstand around 400 psi or so. I have a 3" pipe that will be tapped at both ends and smaller inlets and outlets tapped into the caps for flow. What equation should i use. I know this is kind of elementary, but I cannot remember for the life of me which equation to use and how to go about it.

All help is appreciated.

thanks.






Modified by lancealot72 at Tue, May 24, 2005, 16:57:44

Post Reply | Recommend | Alert View All   | Next |

Replies to this message


Re: Determine thread length by pressure requirements.
Re: Determine thread length by pressure requirements. -- lancealot72 Post Reply Top of thread Forum
Posted by: devitg ®

05/29/2005, 13:33:37

Author Profile Mail author Edit
just meassure the standar fiting to be used to tap the ends.
Look at your hardware shop for a female 3" cap , and made the thread a slight more lenght
As your 100 psi is a NORMAL pressure for a mild steel pipe Schedule 40,you had solve it.






Post Reply | Recommend | Alert Where am I? Original Top of thread
Re: Determine thread length by pressure requirements. Agree
Re: Determine thread length by pressure requirements. -- lancealot72 Post Reply Top of thread Forum
Posted by: Cragyon ®
Bart
05/27/2005, 08:50:15

Author Profile Mail author Edit
On the following page: /mechanics_material_menu.shtml
, at the bottom, there are several pages which give the equations you need. I would use the "Minimum length of thread engagement formula and calculations per FED-STD-H28/2B"

You will need to know the material characteristics.

Additionally, you will have to calculate the effective axial force applied to the pipe thread.






Modified by Cragyon at Fri, May 27, 2005, 08:51:15

Post Reply | Recommend | Alert Where am I? Original Top of thread | |