Mechanical Design, Manufacturing and Engineering Forum
DFM DFA Training and Trainers | Engineering and Design Data | Product Services Directory | Advertise
Engineering Forum | Engineering Specifications Forum |
Engineering and Drafting Store | ASME Y14.5M - 1994 GD&T Training
POSTING POLICY / RULES | Archive#1 | Archive #2 | Archive #3 | Calculators

Forum Moderators: Administrator

Max load for I-beam
Post Reply   Forum
Posted by: Mark Kent ®

07/18/2005, 02:58:28

Author Profile Mail author Edit
Hi All, I am not an engineer but was wondering if one could help me. I have an i-beam supported both ends 3100 mm apart, it is 100mm x 100mm.The eye is 5mm and the ends are 7mm thick. I need to know maxamum load (tons) from weakest point (centre)I would appreciate any help, as the maths is beyond me. Thanks in advance.
Mark






Post Reply | Recommend | Alert View All   | Next |

Replies to this message


Re: Max load for I-beam
Re: Max load for I-beam -- Mark Kent Post Reply Top of thread Forum
Posted by: sblack ®

07/18/2005, 09:20:25

Author Profile Mail author Edit
Hey, I am pretty new to this, but I have just completed a similar project. I used a deflection equation for my analysis.
(5/384) * W(L^3)
EI

This is the maximum deflection at center equation.
You need to know your weight(W), length(L), modulus of elasticity(E), and your moment of interia(I). You know your length, the modulus of elasticity (if steel) is about 29,000,000. I am not sure yet on the moment of interia, I will research. Try to determine weight or you can just plug in numbers and see what your deflection would be.

Shane







Post Reply | Recommend | Alert Where am I? Original Top of thread | |
Re: Max load for I-beam
Re: Re: Max load for I-beam -- sblack Post Reply Top of thread Forum
Posted by: Mark Kent ®

07/18/2005, 16:54:24

Author Profile Mail author Edit
Thanks Shane, I have done some comparisons of similar I beams, and conservatively the beam should weigh about 17kg/meter.
if we use the weight of 50kg total weight, it should be safe. i have no idea of interia.
Thanks Mark






Post Reply | Recommend | Alert Where am I? Original Top of thread | |
Re: Max load for I-beam
Re: Re: Max load for I-beam -- Mark Kent Post Reply Top of thread Forum
Posted by: zekeman ®

07/19/2005, 10:59:48

Author Profile Mail author Edit
What are the loads on this beam? Is it just the weight of the beam or otherwise?






Post Reply | Recommend | Alert Where am I? Original Top of thread | |
Re: Max load for I-beam
Re: Re: Max load for I-beam -- zekeman Post Reply Top of thread Forum
Posted by: Mark Kent ®

07/19/2005, 18:41:43

Author Profile Mail author Edit
It is for a gantry in a workshop. I would like to move about two ton on this beam if possible.

Thanks for your help.

Mark







Post Reply | Recommend | Alert Where am I? Original Top of thread | |
Re: Max load for I-beam
Re: Re: Max load for I-beam -- Mark Kent Post Reply Top of thread Forum
Posted by: zekeman ®

07/21/2005, 16:15:51

Author Profile Mail author Edit
Worst case, the central loading causes a max moment of
FL/4=4000*122/4=122000 lb in
The corresponding stress,s is
s=FL/4(c/I)
where c is the 1/2 width of the crosssection and I is the moment of inertia
For your beam I get c/I=1/4 so the stress is
in excess of 30,000 psi, which is way too high for mild steel.
You need to get a huskier beam or reduce the load by at least 2 and then also check to see whether the max deflection is acceptable.






Post Reply | Recommend | Alert Where am I? Original Top of thread | |
Re: Max load for I-beam
Re: Re: Max load for I-beam -- zekeman Post Reply Top of thread Forum
Posted by: wen101 ®

08/22/2005, 15:03:46

Author Profile Mail author Edit
Hi- I have a related beam question. I am interested in replacing a load bearing wooden beam in my house with steel, and I want to determine the dimensions needed to satisfy the load.

What I am looking for is a conversion of wood dimensions to steel I-beam, as I have no way of knowing what the load is on the wood beams.

Any suggestions? Perhaps a recommended book, or a retail point of contact?

The details are as follows: I'm looking at a beam that is composed of two boards, together yielding dimensions of 3" x 9" x 93", and supported at points up to 12" in from each end. My desire is cut down on the 9" dimensions by using steel or another material, so as to increase the headroom in these doorways.

Thanks,
William







Post Reply | Recommend | Alert Where am I? Original Top of thread

Powered by Engineers Edge