Related Resources: weld

Shielded-Arc Flush Steel Welds Strength Table

Welding Design and Engineering

Strength of shielded-arc flush steel welds table

Type of stress
Limit stress
Recommended design stress
Base metal
elastic limit,
σe
Deposited metal
Elastic limit,
σe

Endurance limit,
σf

Static load
Load varies
from O to F
Load varies
from +F to –F
Tension
MPa
220.60
275.80
151.70
110.30
100.00
55.20
kpsi
32
40
22
16
14.5
8.0
Compression
MPa
241.20
303.40
124.20
110.30
55.23
kpsi
35.0
44.0
10.0
16.0
8.0
Bending
MPa
241.20
303.40
179.30
124.20
110.30
62.10
kpsi
35
44
26
18
16
9.0
Shear
MPa
137.90
165.40
75.80
68.90
34.50
kpsi
20
24
11
10
5
Shear and tension
MPa
75.80
68.90
34.50
kpsi
11
10
5

For bare electrode welds, the allowable stress must be multiplied by 0.8 and for gas welds, they should be multiplied by 0.8 to 0.85.

Source: Design of Weldments, The James F. Lincoln Arc Welding Foundation, Cleveland, Ohio, 1968.