Related Resources: calculators
Fritzsche Formula at Standard Conditions Equation and Calculator
Fluids Engineering and Design Resources
Fritzsche Formula for Pressure Change at Standard Conditions Equation and Calculator
The Fritzsche formula uses the friction factor f calculated from the following equation:
Equation 1
F = 0.02993 ( Ts / ( Ps Qs ) 1/7
where:
f = friction factor
Ts = temperature at standard conditions, °R
Ps = pressure at standard conditions, psia
Qs = volume flow rate at standard conditions, SCFM
The Fritzsche formula for pressure drop then becomes
Equation 2
ΔP = ( 9.8265 x 10-4 ) T L / ( P d5 ) ( Ps Qs / Ts )1.857
where:
ΔP = pressure drop, psi
L = pipe length, ft
d = pipe inside diameter, in
T = airflow temperature, °R
P = average air pressure, psia
Qs = volume flow rate at standard conditions, SCFM
Ps = pressure at standard conditions, psia
Ts = temperature at standard conditions, ◦R
And in terms of flow rate and the upstream and downstream pressures, this becomes
Equation 3
Qs = 29.167 Ts / Ps [ (
P12 - P22 ) d5 ) / ( T L )] 0.538
where:
Qs= volume flow rate at standard conditions, SCFM
Ps = pressure at standard conditions, psia
P1= upstream pressure, psia
P2= downstream pressure, psia
L = pipe length, ft
d = pipe inside diameter, in
Ts = temperature at standard conditions, °R
T = airflow temperature, °R
The preceding formulas can be used for the flow of air at standard conditions and any flowing temperatures. When standard conditions of 14.7 psia and 60°F are used along with a flowing temperature of 60°F, the preceding formulas can be simplified as follows:
Equation 4
ΔP = L Qs1.857 / ( 1480 P d5 )
where:
ΔP = pressure drop, psi
L = pipe length, ft
Qs = volume flow rate at standard conditions, SCFM (see equation 5)
d = pipe inside diameter, in
P = average air pressure, psia
Equation 5
Qs = 1 / 35 [ ( P12 - P22 ) d5 ) / L ]0.538
where:
Qs = volume flow rate at standard conditions, SCFM
P1 = upstream pressure, psia
P2 = downstream pressure, psia
L = pipe length, ft
d = pipe inside diameter, in
Where air pressures are low and close to the atmospheric pressure such as in ventilating work and in airflow through ducts, we can modify the Fritzsche formula to calculate the pressure drops in in H2O. Since 1 in of water column is equal to 0.03613 psi, the pressure loss can be expressed as follows:
Equation 6
h = L Qs1.857 / ( 785 d5 )
where h is the pressure drop measured in in H2O.
Equation 7
Qs = ( 785 h d5 / L )0.538
Related:
- Babcock Steam Flow Rate Formula and Calculator
- Swamee-Jain Friction Factor Equation and Calculator
- Churchill Friction Factor Formulae and Calculator
- Harris Formula Pressure and Fluid Flow Equation and Calculator
- Liquid Pressure Drop in Pipe and Pipe Fittings Spreadsheet Calculator
- Friction Loss - Fluid Flow Hydraulic and Pneumatic
- Darci's Equation Fluids Flow Equation
- Pipe Flow/Friction Factor Calculations with Excel Training - 3 PDH
- Unwin Gas Change of Pressure Calculator and Formulas
- Gas Flow Rate Through Orifice Equations and Calculator per. ISO 5167
- Low Pressure Flow Oliphant and Spitzglass Formula and Calculator
Reference:
- Piping Calculations Manual,
E. Shashi Menon
SYSTEK Technologies, Inc