Related Resources: civil engineering

Concrete Sewer Pipe Dimensions

ASTM C14 Concrete Sewer Pipe Dimensions and Weights

ASTM C14 – Nonreinforced Round Sewer and Culvert Pipe for Nonpressure (Gravity Flow) Applications

Nominal size
(internal diameter)
Minimum wall thickness and required ASTM C14 D0.01-load rating
in and (lbf/ft)
in
mm
class 1a
class 2a
class 3a
4
100
0.625 (1500)
0.75 (2000)
0.875 (2400)
6
150
0.625 (1500)
0.75 (2000)
1.0 (2400)
8
200
0.75 (1500)
0.875 (2000)
1.125 (2400)
10
250
0.875 (1600)
1.0 (2000)
1.25 (2400)
12
300
1.0 (1800)
1.375 (2250)
1.75 (2500)
15
375
1.25 (2000)
1.625 (2500)
1.875 (2900)
18
450
1.5 (2200)
2.0 (3000)
2.25 (3300)
21
525
1.75 (2400)
2.25 (3300)
2.75 (3850)
24
600
2.125 (2600)
3.0 (3600)
3.375 (4400)
27
675
3.25 (2800)
3.75 (3950)
3.75 (4600)
30
750
3.5 (3000)
4.25 (4300)
4.25 (4750)
33
825
3.75 (3150)
4.5 (4400)
4.5 (4850)
36
900
4.0 (3300)
4.75 (4500)
4.75 (5000)

(Multiply in by 25.4 to obtain mm.)
(Multiply lbf/ft by 14.594 to obtain kN/m.)
aAs defined by the strength (D-load) requirements of ASTM C14.

Reference

ASTM C14, Standard Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe

Related